Ask what a kitchen hood costs and you will get answers between $15,000 and $150,000, because the question is being answered about different things. The stainless canopy over the cooking line is a minor purchase. The system it belongs to — welded duct to the roof, a fan sized to the hood, a second rooftop unit bringing tempered air back in, a suppression system engineered to your exact appliance positions, and the structure to carry all of it — is usually the largest single mechanical cost in a restaurant fit-out.
This guide prices the package. Commercial kitchen ventilation, explained covers how the system works and why each part exists; this one is about the money and the code behind it.
What you are actually buying
| Part | What it is |
|---|---|
| The hood | The canopy and filters over the cooking line. Type 1 for grease-laden vapour, Type 2 for heat and steam only. |
| Welded grease duct | The route from the hood to the roof. Welded, sealed, and fire-rated where it passes through construction. |
| Exhaust fan | Sized to the hood’s exhaust volume, mounted on a curb on the roof. |
| Make-up air unit | A second rooftop unit that heats and delivers replacement air for everything the hood removes. |
| Fire suppression | A wet chemical system to UL 300, with nozzles positioned for your specific appliances, tied to gas shut-off and the alarm. |
| Structure and roof work | Curbs, reinforcement and penetrations for two rooftop units. |
| Balancing and commissioning | Measuring and adjusting exhaust against make-up air, and the report that proves it. |
Only the first line is the thing most people picture, and it is typically about a fifth of the total.
What it costs
A Type 1 hood canopy itself runs $1,200 to $1,900 per linear foot installed, as an NHFC planning band — so a 12-foot cooking line is roughly $14,000 to $23,000 of hood. The chart at the top of this page gives the installed band for every other part of the package.
For a typical single cooking line in a restaurant, the whole installed package lands at $50,000 to $95,000.
Read those bands and this total together rather than adding the bands up. The high end of every line does not happen on one project: a long vertical duct run, structural reinforcement, a solid-fuel appliance and a difficult roof can stack to well past $150,000, but that is a hard site, not a typical one. If several of the drivers below apply to your space, price it properly before you sign anything.
Against the buildout range the cost calculator returns for a 2,400 sq ft restaurant renovation — $360,000 to $670,000 — a hood package at $50,000 to $95,000 is roughly a tenth to a quarter of the whole fit-out. That share is the useful number to carry into a feasibility conversation, because it scales with the project in a way a dollar figure does not.
These are planning bands from our own projects. Unlike permits and the liquor licence, where the issuing authority publishes a fee schedule you can check, nobody publishes hood prices. That is exactly why the answers online vary by a factor of ten, and it is why a real quote against real drawings is worth getting early.
For the equipment side of that quote, our equipment partner Norpex has a commercial kitchen hood builder. You line up your appliances, the hood sizes itself to the line, and a quote for the hood, the exhaust fan, the make-up air unit and the fire suppression comes back by email at no charge. The parts that depend on the building — the duct route, the structure and the roof — still need someone to look at the site and the drawings.
Two codes, not one
The hood sits under two regulations that people routinely conflate, and knowing which is which tells you who to ask.
The Building Code governs installation. All commercial cooking equipment has to be provided with ventilation systems designed, constructed and installed to conform to NFPA 96. Fire protection systems for commercial cooking equipment using vegetable oil or animal fat have to conform to ANSI/CAN/UL/ULC 300 or ULC/ORD-C1254.6. There is also a dimension worth checking before the duct route is fixed: the Building Code sets a minimum 3.0 m between a kitchen exhaust outlet and an outdoor air intake, which on a tight roof can decide where the fan goes and how long the run is.
The Fire Code governs operation and maintenance. A cooking operation producing smoke or grease-laden vapours has to be provided with an exhaust system and a fire protection system in accordance with NFPA 96, and those systems have to be maintained in accordance with NFPA 96. Instructions for operating the suppression system manually have to be posted conspicuously in the kitchen, and included in the fire safety plan where one is required.
In short: the building department signs off that it was built right, and the fire service checks for the rest of the restaurant’s life that it is being kept right.
The second-generation trap
A space with a hood already in it is a genuine asset — and the Fire Code is explicit that an existing exhaust or fire protection system may be approved. That word is doing a lot of work, though, and there are three ways an inherited system turns out to be worth less than the lease negotiation assumed.
It is the wrong type or the wrong size. A Type 2 hood over your fryer is not a discount, it is a code problem. A 10-foot hood over a 14-foot line is a shorter line or a second hood.
The suppression system predates UL 300. Older dry chemical systems were designed around the cooking oils and appliance types of an earlier era. The current standard is wet chemical to UL 300, and a pre-UL 300 system above a working cooking line is a replacement, not an inspection. This is the single most common unbudgeted surprise in a second-generation kitchen.
The duct is not where you need it, or not in the condition you assumed. Grease duct that has not been cleaned or inspected, a route that no longer suits your layout, or a landlord who will not permit a new roof penetration all turn an inherited asset into a partial one.
Three questions settle it before the lease: what type and length is the hood, when was the suppression system last serviced and does it meet UL 300, and has the duct been cleaned with the record to prove it. Choosing a space covers the rest of that inspection.
What moves the number most
The ventilation guide lists the mechanical drivers in order of impact. In money terms the three that most often blow a hood budget are:
- Distance to the roof. Duct run length is the clearest multiplier in the package. A ground-floor unit under its own roof is a different project from a unit on the first floor of a three-storey building, where the duct has to be boxed, rated and routed through somebody else’s space.
- Structural capacity. Two rooftop units need curbs and, often, reinforcement. This is rarely in a first budget and never cheap.
- Solid fuel. Wood or charcoal brings a separate duct system, spark arrest and its own cleaning regime, and it is the one menu decision that reliably changes the mechanical scope.
Two more worth pricing early: whether the gas and electrical services can actually carry a heated make-up air unit and an exhaust fan — see power and gas — and whether the landlord permits the roof penetrations at all.
What it costs to run
This is where most published advice is confidently wrong, because it quotes an interval that is not in Ontario law.
The one fixed frequency is weekly. The Fire Code requires that hoods, ducts and filters subject to accumulations of combustible deposits be checked at intervals not greater than seven days, and cleaned if the accumulation creates a fire hazard. That is a check by you, not a visit by a contractor.
The cleaning interval comes from NFPA 96, and it depends on your cooking. The Fire Code adopts NFPA 96 for maintenance rather than setting a number, and NFPA 96 scales inspection frequency to how much and what you cook. A charbroiler running all day and a bakery oven are not on the same schedule. Ask your service provider which category your operation falls into and get it in writing.
Keep the records. Where the Fire Code requires a measure to be carried out, a record has to be made noting what was done and the date and time it was done. The fire inspector will ask for the service record, and “we have it done regularly” is not one.
Budget $2,000 to $6,000 a year for cleaning and suppression service on a single-hood restaurant as an NHFC planning band, scaling with hood length, duct run and cooking volume. The costs that arrive after you open puts that beside the rest of the operating picture.
Where the budget usually goes wrong
- The hood is priced and the package is not. A supplier quote for a canopy is not a system cost. Duct, fan, make-up air, suppression and structure are four to five times the hood.
- Make-up air is discovered late. It is a second rooftop unit with its own gas, power and structure, and it is the line most often missing from an early number.
- The layout changes after suppression is designed. Nozzles are positioned for specific appliances in specific places. Moving the fryer means re-engineering the system.
- An inherited system is assumed to be compliant. A hood that exists is not a hood that passes.
- Nobody checks the roof. Structural capacity and permission to penetrate are both assumptions until somebody confirms them.
Getting the hood right starts with the equipment layout being final, because every number above follows the appliance line. That coordination — drawings where the kitchen layout, the mechanical and the suppression design agree before anything is ordered — is the part that keeps this package from being the line that moves your opening date.
Requirements change and the authority having jurisdiction decides any specific project. Check each one for your address before you rely on anything here.
Sources
- Ontario Building Code, O. Reg. 163/24 (the 2024 Building Code), Division B, Article 6.3.1.6. (commercial cooking equipment ventilation to NFPA 96), Article 6.9.1.3. (suppression to ANSI/CAN/UL/ULC 300 or ULC/ORD-C1254.6) and Table 6.3.2.9. (3.0 m from a kitchen exhaust outlet to an outdoor air intake): 2024 Building Code Compendium, Part 6
- Fire Code, O. Reg. 213/07, Articles 2.6.1.3. (check at intervals not greater than seven days), 2.6.1.12. (exhaust and fire protection to NFPA 96; an existing system may be approved), 2.6.1.13. (maintenance to NFPA 96) and 2.6.1.14. (manual operating instructions posted and in the fire safety plan), and Article 1.1.2.1. (records of what was done and when): ontario.ca/laws/regulation/070213
- NFPA 96, Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, adopted by reference in both codes above. The standard itself sets the inspection frequencies.
The code references in this guide were checked against e-Laws and the 2024 Building Code Compendium on 31 October 2026, and the Building Code articles re-checked on 8 November 2026. The dollar figures are NHFC planning bands from our own Ontario projects, not published prices — no authority publishes hood costs, and a quote against real drawings will always beat a range.